Fault Finding Chart 2
2
Is heater plumbed
correctly?
YES
NO
NO
Remake plumbing to comply
with installation instructions.
Ensure plumbing valves are
open or in correct postion.
Are plumbing valves open
or in correct position?
Is water temperature
probe resistance value
correct?
YES
Refer to section „testing water
temperature thermistors‟
Replace water temperature
probe.
NO
Is inlet gas pressure
within specification?
YES
Is burner flame
satisfactory?
YES
Burner flame should be blue with little
or no yellowing of the tips. Burner
flame should not be a harsh noisy blue
flame.
NO
Are burner injectors
correct size and gas
type?
Refer to „Gas Valve‟ section.
YES
Can burner gas pressure
be correctly adjusted?
Replace burner injectors with
injectors of correct size and
gas type.
NO
NO
Burner gas pressure correctly
adjusted.
YES
NO
YES
Advise customer.
NO
Replace gas valve.
Advise customer that supply
gas is of a bad quality and is
unsuitable for heater
operation.
NO
Natural gas
What type of heater is
installed?
Is gas of a suitable
quality?
Propane
YES
Refer to specification table.
Is in/out header bypass
valve stuck open?
Free or replace bypass valve.
YES
Does in/out header
bypass valve have
correct spring?
Replace bypass valve spring
with one of the correct colour.
NO
YES
NO
Pool heater operating
correctly. Pool may be loosing
temperature due to low
ambient air temperature or
adverse weather conditions.
Advise customer to fit a pool
cover.
Check & adjust burner gas
pressure.