Fault Finding Chart 1.8
Is burner gas pressure
within specification?
1.8
Is burner flame
satisfactory?
NO
YES
Heater operating. Check
heater operation to ensure
heater high limits do not trip
due to excessive temperature.
Burner flame should be blue with little or
no yellowing of the tips. Burner flame
should not be a harsh noisy blue flame.
Refer to specification table.
YES
Refer to specification table.
Does 45º inlet or 55º
outlet high limit trip?
4
YES
Is flame wind affected?
NO
YES
Is inlet gas pressure
within specification?
Advise customer.
NO
Heater operating correctly.
NO
4.1
Refer to section on adjusting
burner gas pressure.
Burner gas pressure adjusted.
Check appliance operation.
Can burner gas pressure
be adjusted?
YES
NO
NO
NO
Replace gas valve.
YES
Create wind break or
reposition heater.
Possible bad gas supply.
Are burner injectors
correct size and gas
type?
YES
Are burner injectors
partially blocked?
YES
NO
Clean or replace burner
injectors
Replace burner injectors with
injectors of correct size and
gas type.