TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
24
Fault Finding Chart 1.4
Is Error code
„SC‟ or „F3‟ displayed?
1.4
Is Error code
„OC‟ or „F2‟ displayed?
NO
Is water temperature
probe plug firmly plugged
into control board socket?
YES
NO
Firmly plug water temperature
probe into control board
socket?
Is water temperature
probe resistance value
correct?
YES
Replace water temperature
probe.
NO
Replace control board.
YES
YES
Is error code
„SS‟ or „F4‟ displayed?
NO
Is solar water
temperature probe
resistance value correct?
Replace solar water
temperature probe.
YES
NO
Replace control board.
YES
Is solar water temp probe
wiring ok?
Repair solar water
temperature probe wiring.
NO
YES
Is Error code
„PO‟ displayed?
YES
1.2
Is Error code
„o‟ displayed?
NO
Is the pump operating?
YES
NO
YES
Water temperature
probe open circuit
Water temperature
probe short circuit
No power at
control board
Pressure switch open
during call for heat
(Black boards only)
Is the water pressure or
flow switch closed?
5
Is there sufficient water
flow through the heater?
NO
Can the water pressure
or flow switch be
adjusted?
YES
Adjust water pressure or flow
switch.
YES
Replace water pressure or
flow switch.
NO
Min flow rate 1.3 l/sec
Max flow rate 6.9 l/sec
Refer to section on adjusting
pressure switch or adjusting
flow switch
NO
YES
Replace control board.
NO
Solar water temperature
probe open circuit
Error code
„F1‟ is displayed.
Rework required. Contact
Rheem Service.
YES
NO
Heater rework required
Test 21
Test 21
Pump must be operating for
burner to operate.
Test 10A for black boards.