Fault Finding Chart 1.1
1.1
Unplug heater power supply cord
set from GPO.
Did fuse blow
again?
Household wiring, power point or
another connected appliance is
faulty. Advise customer to call an
electrician.
YES
NO
Is reading less than 1
mega-ohm for either
reading
Replace heater power supply cord
set.
YES
NO
Replace transformer.
YES
Look for damaged or pinched wiring
touching the heater chassis.
NO
Disconnect heater power supply
cord set from line terminal block and
megger between cord set active and
earth pins then cord set neutral and
earth pins.
Replace fuse.
Is reading less than 1
mega-ohm for either
reading
Disconnect transformer at line terminal
block and measure between each
transformer wire and earth.
Fault Finding Chart 1.2
1.2
Is 24 volts present at
control board
terminal marked
„24VAC‟
Is 240 volts present
at line terminal block?
YES
NO
NO
NO
Replace heater power supply cord
set.
Replace control board.
YES
Has the control circuit
fuse blown?
Replace transformer.
Faulty fuse replaced, check
appliance operation.
YES
Did control circuit
fuse blow again?
NO
Resistance values for each control
circuit component will need to be
checked against resistance values in
specification table to locate the faulty
component or faulty wiring.
YES
Test 8A for black boards
Test 8B for grey boards
Test 9
Test 9
Test 7
Replace control
circuit fuse.