TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
8
Lighting Instructions
Main Burner
1.
STOP
read all of the safety information in the installation and operating instructions.
2. Press the pool heater
Power
button until the display is off.
3. Turn
OFF
all electrical power to the pool heater.
4. The pool/spa heater is equipped with an automatic ignition system, which lights the
burner.
5. Wait five (5) minutes to clear out any unburnt gas.
STOP
if you smell gas and follow
the safety instructions in the installation and operating instructions. If you do not smell
any gas go to the next step.
6. Turn the gas isolation valve to the
ON
position.
7. Turn on electrical power to the pool/spa heater.
8. Press and release the red reset button, the reset light should go out. NOTE: For
models manufactured from 14/04/09 onwards the reset button should NOT illuminate
and does not need to be pressed.
9. Press and release the
Power
button on the control panel and set the thermostat to the
desired setting.
10. The burner should light.
If the pool heater is not equipped with a red reset button, contact Rheem
Service.
To turn off the pool heater
1. Press the
Power
button on the control panel and wait for the display to extinguish
(
„OFF‟ position).