8.1 i50 Tridata operation
When connected to the relevant transducer(s) your
i50 Tridata instrument:
• Provides depth information in either feet (FT) or
metres (M).
• Enables you to define alarm thresholds for shallow
alarm, deep alarm, shallow anchor alarm and
deep anchor alarm.
• Provides speed information (current, maximum
and average), in either knots (KTS), miles per hour
(MPH) or kilometers per hour (KPH).
• Velocity made good (VMG) information, VMG
is only available when connected to SeaTalk
or SeaTalk
ng
network which also contains a
compatible wind transducer.
• Provides log and trip information. These are given
in either nautical miles (NM), statute miles (M) or
kilometers (KM).
• Provides water temperature information. This is
given in either degrees celsius (ºC) or degrees
fahrenheit (ºF).
• Provides count up and race start timer functions.
Note:
Depth information is obtained from the depth
transducer connected to the unit. However, when
the instrument is connected to a SeaTalk network,
which contains a compatible sonar module
(fishfinder) the depth information is provided by the
sonar module whilst it is switched on.
It should be noted that:
• The required units of measurement are set during
User calibration.
• Up / Down depth-trend arrows are displayed, if the
seabed is rising or falling at a significant rate.
• The log screen shows the total distance covered
by the vessel since the unit was fitted.
• Maximum speed, average speed and trip reading
are reset to zero at power up.
• If for any reason depth information is lost, the
depth title will flash and the displayed value will be
the last known depth reading.
i50 Tridata display layout
The i50 Tridata display is divided into 3 separate
areas, each of which displays a separate type of
information, as shown below.
D12537-2
D
e pth
S pe e d
Trip
Re s e t
1
2
3
1
Depth information
2
Speed information
3
Trip, log, water temperature
and timer
8.2 i50 Tridata controls
Depth
Speed
Trip
Re s e t
D13146-1
1
2
3
4
1
Depth / Power
— Select to access Depth
information, adjust backlight, adjust contrast and
power the display On and Off
2
Speed
— Select to access Speed and VMG
information
3
Trip / Down
— Select to access log, trip and water
temperature information. Use to move down through
menu options or to decrease numeric values
4
Reset / Up
— Select and hold down for 3 seconds
to reset data to current values. Use to move up
through menu options or to increase numeric values
56
i50
Summary of Contents for i50 Depth
Page 2: ......
Page 4: ......
Page 10: ...10 i50...
Page 32: ...32 i50...
Page 42: ...42 i50...
Page 78: ...78 i50...
Page 86: ...86 i50...
Page 88: ...88 i50...
Page 89: ......
Page 90: ...www raymarine com...