4.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type
and length
• Unless otherwise stated use only standard cables
of the correct type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the
correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize
performance and prolong cable life.
• Do NOT bend cables excessively. Wherever
possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
100 mm (4 in)
200 mm (8 in)
• Protect all cables from physical damage and
exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing
twine. Coil any extra cable and tie it out of the way.
• Where a cable passes through an exposed
bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or fluorescent
lights.
Always route data cables as far away as possible
from:
• other equipment and cables,
• high current carrying ac and dc power lines,
• antennae.
Strain relief
Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.
Cable shielding
Ensure that all data cables are properly shielded
that the cable shielding is intact (e.g. hasn’t been
scraped off by being squeezed through a tight area).
4.2 Power connection
Power is supplied to the product over the SeaTalk
ng
network.
A SeaTalk
ng
system requires one 12 V dc supply,
connected to the SeaTalk
ng
backbone. This can be
provided:
• By a battery via the distribution panel, or
• From a Raymarine course computer, via a SeaTalk
or a SeaTalk
ng
system.
Warning: Grounding not required
This product is fully insulated and does
NOT require separate grounding.
Warning: Positive ground systems
Do not connect this unit to a system which
has positive grounding.
Power connection
Direct power connection
+
_
D13137-1
2
1
4
3
1
3 A circuit breaker or fuse
2
12 V dc vessel power supply
3
Vessel’s RF ground
4
SeaTalk
ng
power cable
Example
SeaTalk
ng
D12391-2
1
2
8
6
3
5
4
7
12 V dc
1
SeaTalk
ng
instrument
2
SeaTalk
ng
Pilot controller
3
12 V dc vessel power supply.