65
i4000 Lattice Crane
Instruction Manual
55M4000EBE00 Rev C
Absolute rotation
The i4000 system can communicate with only one rotation sensor. The rotation interface is
activated through the calibration menu in the ‘‘Enable/Disable sensors’’section.
D) Rotation Sensor J1939 error
Absolute rotation (same position kept at all times)
Error message
Runtime process
Error cause
Rotation 1: Ratio not set
The system detects a ratio of
0.
No ratio has been entered or
calibrated.
Rotation 1:
Lost communication
The system has not received
a valid message from the
rotation interface within the
required time frame.
1) The rotation interface is
faulty..
2) The cable linking the
interface to the bus CAN
network is broken.
5.5.2 External peripherals (cont.)