55M4000EBE00 Rev C
46
i4000 Lattice Crane
Instruction Manual
4.6 System in absolute limiting mode
In absolute limiting mode, the operator can set, activate or deactivate five operational limits.
These are:
1) The minimum boom angle limit.
2) The maximum boom angle limit.
3) The maximum boom length limit.
4) The maximum boom head height limit.
5) The maximum work radius limit.
Please make sure you have read and understood these
instructions before defining the operational limits. A wrong
setting of operational limits can lead the machine to collide
with obstacles and thus cause serious injuries or death.
Important: Please note that no brake measures are applied on absolute
limits.
Absolute limits are fixed limits. They can be used as absolute reference values.