8.15 ) Temperature Sensor Placement
You have been provided with two (2) Temperature Sensors which are specifically
designed to work with this system. Each Sensor has fifteen (15) feet of cable. These
Sensors are plugged into the system Control POD (the two plugs next to the antenna port
– opposite side of the wiring harnesses). Care should be taken before deciding where their
final mounting point should be. We have provided hook and loop fasteners (Velcro®) to
secure these Sensors. Place the cable under the Velcro® so that the black Temperature
Sensor is completely exposed.
Consider:
•
Neither Sensor should be mounted in a position that is subject to direct sunlight nor in
close proximity to air conditioning vents or the roof of the vehicle -- Doing so will give
incorrect readings of the “true” temperature inside the vehicle.
•
Cables should be routed to avoid points of possible abrasion.
•
Be certain the K9 cannot get to the sensors. They are
not
chew proof.
8.16 ) Lights and Horn Connection
It is recommended to run the light and horn output wires into the engine compartment.
Connect the horn output directly at the horn itself. The light output can be connected to
the parking lights wire which will light all four corners of the vehicle.
8.17 ) MD10 F Ray Allen Fan Connection
The Ray Allen MD10 F Fan is designed to bolt directly to either side of the front panel on
the Ray Allen Cruise Eze™. Hardware for this installation is included with the Fan. When
attaching the Fan to the front panel of your Cruise Eze™, we suggest you insert the bolts
and washers from inside of the cage and place the nut on the Fan side. You do not want
the nut on the inside of the cage as it has a higher profile than the bolt head and this may
injure the dog.
Also included is the wiring to connect directly to the system’s Control POD. To complete
this connection, attach the fan output wire from the POD to the black wire on the fan (butt-
splices are included for this connection). Connect the blue wire from the fan to a positive
battery voltage. The POD is designed to control only one fan. Therefore, do not connect
the POD's fan wire to multiple fans. Test this connection when testing the complete
system. This fan is designed to blow “in” to the Cruise Eze™ unit. If for some reason you
wish this fan to blow in the opposite direction, simply reverse these wire connections.
F3-G2 System Manual - Rev 7