The Ravenheat boiler is supplied for con-
nection to a 230 V - 50 Hz single phase
supply.
The supply must be fused at 3 A.
NOTE: The method of connection to the
electricity supply MUST facilitate complete
electrical isolation of the appliance, by the
use of a fused, double pole isolator, having
a contact separation of at least 3 mm in all
poles. The point of connection to the elec-
tricity supply must be readily accessible
and adjacent to the appliance except,
where the appliance is installed in a bath-
room, this MUST be sited outside the bath-
room.
SECTION
5 INSTALLATION
5.1
5.1.1
5.2
5.2.1
14
WARNING
It is MOST IMPORTANT that this appliance
is installed in a VERTICAL POSITION, with
the flue air duct passing through the wall in
a HORIZONTAL PLANE. A minor deviation
from the horizontal is acceptable, provided
that this results in a downward slope of the
flue/air duct away from the combination
boiler.
DELIVERY
The appliance will arrive on site in two
cartons:
Boiler carton containing
(Fig. 10-l 1):
a) boiler fully assembled
b) installation instructions and
user instructions
c) white paper template
d) terminal cover plate (Fig. 12)
e) - 4 coach bolts and wall plugs
- screws and dowels
Polythene bag containing:
a) 2-22 mm compression ball valves
(heating)
b) 1-15 mm compression ball valve
(with drain screw for domestic cold
water inlet)
c) 1-1/2” BSP Union gas cock
d) - 2 15 mm flanged copper tails complete
with 1/2” brass nuts and washers
- 2 22 mm flanged copper tails complete
with 3/4" brass nuts and washers
Fig. 10
Fig. 11
Summary of Contents for RSF 82E
Page 39: ...Fig 93 Fig 91...
Page 42: ...SECTION 9 ELECTRICAL SYSTEM DIAGRAM Fig 94...
Page 43: ...44...
Page 44: ...45...
Page 45: ...46...
Page 46: ...SECTlON IO EXPLODED PARTS DIAGRAM...
Page 49: ...NOTES...
Page 50: ...Chartists Way Morley Leeds LS27 9ET Telephone 0113 252 7007 Tfax 0113 238 0229...