GAS CONNECTION (Fig. 46)
A minimum gas pressure of 20 mbar (6 in
w.g.) must be available at the boiler inlet at
full flow rate.
Fit gas service cock to the boiler via the
union nut and connect gas pipe.
Do not overtighten and use another
spanner as a counter force to avoid
straining internal connections.
Important: Consult sect. 4.5.1
CENTRAL HEATING CONNECTION
(Fig. 46)
Before any central heating connections are
made to the boiler all system valves should
be opened and the system thoroughly
flushed out with cold water.
- Connect the central heating return pipe
to the isolating cock marked CHR.
- Connect the central heating flow pipe to
the isolating cock marked CHF.
-
Pipe dimension’s and position are marked
on template supplied and Fig. 49 A
DOMESTIC HOT WATER (Fig. 46)
The domestic hot water circuit does not need
a safety valve but it is essential to ensure that
the pressure of the cold water supply does
not exceed 10 bar. If in doubt it is advisable to
install a pressure reducing valve. The
minimum pressure needed to operate the
domestic hot water system is 0.5 bar
with a flow of approx 3 Lts per min. The
regulator screw on the cold water outlet of
the diverter valve may be adjusted to
prevent excess volume flow (Fig. 53
COMMISSIONING SECTION). Flush out all
foreign matter from the supply pipe before
connecting to the appliance.
- Connect the 15 mm. cold water pipe to
the stop cock to the appliance inlet
marked DCW.
Fig. 44
Fig. 45
- Connect the 15 mm. hot water pipe with
a suitable connection.
23
Summary of Contents for RSF 82E
Page 39: ...Fig 93 Fig 91...
Page 42: ...SECTION 9 ELECTRICAL SYSTEM DIAGRAM Fig 94...
Page 43: ...44...
Page 44: ...45...
Page 45: ...46...
Page 46: ...SECTlON IO EXPLODED PARTS DIAGRAM...
Page 49: ...NOTES...
Page 50: ...Chartists Way Morley Leeds LS27 9ET Telephone 0113 252 7007 Tfax 0113 238 0229...