7.19.4
7.19.5
7.20
7.20.1
7.20.2
7.20.3
7.20.4
7.21
7.21 .1
7.21.2
7.21.3
7.21.4
7.21.5
7.22
7.22.1
7.22.2
7.22.3
7.22.4
7.22.5
7.22.6
Unscrew the lock nut which fastens the
potentiometer to the instrument panel (Fig. 78).
Replace in reverse order
TO REMOVE/REPLACE THE MAIN
SWITCH (Fig. 82).
Remove the front panel from the outer
casing (sect. 7.3), lower the instrument
panel (sect. 7.16.2 & 3), remove the control
box cover (7.31.2/3) and remove the control
knob.
Detach the wires that connect to the switch
-
make sure that these wires are later
reconnected to the same poles (Fig. 94).
Pull the switch out from the instrument
panel by pressing the clamp springs.
Replace in reverse order
TO REMOVE/REPLACETHE WATER
PRESSURE GAUGE (Fig. 83).
Remove the front panel from the outer
casing (sect. 7.3) and lower the instrument
panel (sect. 7.16.2 & 3).
remove the lower grating (sect. 5.4.2).
Close the heating system on/off valves and
drain the water from the drain point on the
heating system (Fig. 93).
Unscrew the fitting that secures the
pressure gauge probe.
Remove the gauge from the instrument
panel by pressing its fastening springs.
Replace in reverse order.
TO REMOVE/REPLACE THE OVERHEAT
THERMOSTAT
Remove the front panel from the outer
casing (sect. 7.3) and lower the instrument
panel (sect. 7.16.2 & 3) and remove the
control box cover (7.31.2/3).
Remove lower grill and right side of the
casing (sect. 5.4.2 & 5).
Remove the three wires that connect to the
overheat thermostat - making sure that
these
wires
will
subsequently be
reconnected to the same poles (Fig. 94).
Unscrew the plastic cover and locknut that
fastens the overheat thermostat and remove it.
Remove the split pin and pull the thermostat
sensor from its pocket complete with case
sealing grommet.
Remove case sealing grommet from the old
thermostat and fit to new one.
7.22.7
7.23
7.23.1
7.23.2
7.23.3
7.23.4
7.23.5
7.23.6
7.24
7.24.1
7.24.2
7.24.3
7.24.4
7.24.5
7.24.6
7.25
7.25.1
7.25.2
Replace in reverse order.
TO REMOVE/REPLACE THE ELECTRIC
CONTROL BOARD (PCB)
Remove the front panel from the outer
casing (sect. 7.3) and lower the instrument
panel (sect. 1.16.2 & 3).
Unscrew the 2 screws holding the control
box cover and remove.
Disconnect mains cables and any other
connections (room thermostat and frost
thermostat if fitted).
Detach the connectors from the board.
.
Detach the PCB board from its base by
unscrewing the six screws.
Replace in reverse order (ensure all
electrical connections are made correctly).
Having replaced PCB recommission boiler
on heating mode (sect. 6.15).
TO REMOVE/REPLACE THE DIFFEREN-
TIAL PRESSURE SWITCH (Fig. 87).
Remove the front panel from the outer
casing and the combustion chamber front
cover (sect. 7.3 & 4).
Detach the wires that connect to the pressure
switch, make sure that these wires are later
reconnected to the same poles (Fig. 94).
Unscrew the two screws that fasten the
pressure switch to the back of combustion
chamber.
Remove the two silicone tubes.
Ensure tubes are connected correctly (Fig.
87) avoiding kinks.
Replace in reverse order ensuring that the
- t a p p i n g i s c o n n e c t e d t o t h e t u b e
terminating inside the case and the +
tapping is connected to the tube terminating
at flue ring (Fig. 87 and 94).
TO REMOVE/REPLACE THE PUMP
(Fig. 88)
Remove the front panel from the outer
casing (sect. 7.3) and lower the instrument
panel (sect. 7.16.2 & 3).
Remove lower grill right side of the casing
(sect. 5.4.2 & 5), lower the electric box
(sect. 7.16.2 & 3).
36
Summary of Contents for RSF 82E
Page 39: ...Fig 93 Fig 91...
Page 42: ...SECTION 9 ELECTRICAL SYSTEM DIAGRAM Fig 94...
Page 43: ...44...
Page 44: ...45...
Page 45: ...46...
Page 46: ...SECTlON IO EXPLODED PARTS DIAGRAM...
Page 49: ...NOTES...
Page 50: ...Chartists Way Morley Leeds LS27 9ET Telephone 0113 252 7007 Tfax 0113 238 0229...