SECTION 3
TECHNICAL DATA
HE PRIMARY AAA
TABLE 1
NATURAL GAS (G 20)
І
2H
-
П
2H3+
NOMINAL HEAT INPUT NET QMS
22.6 kW
MINIMUM HEAT INPUT NET
11.6 kW
NOMINAL HEAT OUTPUT
22.3 kW
MINIMUN HEAT OUTPUT CONDENSING
23.9 kW
NOMINAL HEAT OUTPUT
11.4 kW
MINIMUM HEAT OUTPUT CONDENSING
12.3 kW
GAS RATE
Max
2.3 m
3
/h
AFTER 10 MINUTES
min
1.2 m
3
/h
INLET PRESSURE
20 mbar
BURNER PRESSURE
max
10.5 mbar
min
2.0 mbar
BURNER INJECTORS
Nr. 13 x 1.25
ELECTRICAL SUPPLY
230V ~ 50 Hz
POWER CONSUMPTION
60 W
EXTERNAL FUSE RATING
3 A
INTERNAL FUSE
2 A
DRY WEIGHT
35 kg
WATER CONTENT C H
0.5 litre
GAS SUPPLY CONNECTION C H
15 mm
FLOW CONNECTION C H
22 mm
RETURN CONNECTION C H
22 mm
CONDENSATION DRAIN
3/4” (21.5 mm) push fi t over fl ow
SEALED WATER SYSTEM C.H.
MAX PRESSURE PMS
2.5 bar
MINIMUM WORKING PRESSURE
0.5 bar
CENTRAL HEATING OPERATING TEMPERATURE
MAX - 85 °C
min - Off
FLUE OUTLET NOM. DIAMETER 60/100 mm specially supplied with boilers
DESTINATION : AT, DK, Fl, SE
CATEGORY I
2H
DESTINATION: GB, IE, CH, ES, IT, PT
CATEGORY II
2H3+
FLUE TYPE: C
12
- C
32
- C
52
NOX 4
Summary of Contents for HE Primary AAA
Page 16: ...Supplied By www heating spares co Tel 0161 620 6677 17 Fig 18...
Page 31: ...Supplied By www heating spares co Tel 0161 620 6677 Fig 58 32 Fig 56 Fig 57...
Page 33: ...Supplied By www heating spares co Tel 0161 620 6677 34 Fig 60 Fig 61 Fig 62 Fig 63...
Page 42: ...Supplied By www heating spares co Tel 0161 620 6677 section 10 EXPLODED PARTS DIAGRAM 43...