Thoroughly wash hands and face after using agricultural chemicals and before eating, drinking, or
using the rest room.
•
Thoroughly flush or rinse equipment used to mix, transfer, or apply chemicals with water after use
or before servicing any component of the application system.
• Follow all federal, state, and local regulations regarding the handling, use, and disposal of agricultural
chemicals, products, and containers. Triple-rinse and puncture or crush empty containers before disposing of
them properly. Contact a local environmental agency or recycling center for additional information.
ELECTRICAL SAFETY
• Always verify that the power leads are connected to the correct polarity as marked. Reversing the power leads
could cause severe damage to the equipment.
• Disconnect the system ECUs and control console before jump starting the vehicle or welding on any part of the
implement or machine.
INSTRUCTIONS FOR WIRE ROUTING
The word harness is used to mean all electrical leads and cables, bundled and unbundled. When installing harness,
secure it at least every 30 cm (12in) to the frame. Follow existing harness as much as possible and use these
guidelines:
Harness should not contact or be attached to:
• Lines and hoses with high vibration forces or pressure spikes
• Lines and hoses carrying hot fluids beyond harness component specifications
Avoid contact with any sharp edge or abrading surfaces such as, but not limited to:
• Sheared or flame cut edges
• Edges of machined surfaces
• Fastener threads or cap screw heads
• Ends of adjustable hose clamps
• Wire exiting conduit without protection, either ends or side of conduit
• Hose and tube fittings
Routing should not allow harnesses to:
• Hang below the unit
• Have the potential to become damaged due to exposure to the exterior environment. (i.e. tree limbs, debris,
attachments)
• Be placed in areas of or in contact with machine components which develop temperatures higher than the
temperature rating of harness components
• Wiring should be protected or shielded if it needs to route near hot temperatures beyond harness component
specifications
Harnessing should not have sharp bends.
CAUTION
Summary of Contents for Sidekick Pro
Page 12: ...CHAPTER 2 10 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 84: ...CHAPTER 7 82 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 88: ...CHAPTER 8 86 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 91: ...System Diagrams Electrical 89 SYSTEM DIAGRAMS FIGURE 2 Single Pump System Diagram ...
Page 93: ...System Diagrams Electrical 91 SYSTEM DIAGRAMS PLUMBING FIGURE 4 Dual Pump Injection Plumbing ...
Page 96: ...Index 94 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...