Sidekick Pro™ ISO Installation & Operation Manual
1. Select the Tools icon from the soft keys area on the right side of the Product Control Home screen.
2. Touch the Alarms icon along the top of the display to access the Alarms Setup screen.
Refer to the following sections for details on the alarm settings available on the Alarms Setup screen.
LOW TANK
Enter the volume at which the system will display an alert when the calculated volume of product remaining in the
tank drops below the desired value. Enter a value of zero to disable the low tank alarm.
OFF RATE
Enter the percent at which the off rate alarm will activate. The off rate alarm activates when the actual rate differs
from the target rate by the programmed value for longer than five seconds.
FER CAL
The FER (Flow Encoder Ratio) cal value is used to set the flow error tolerance of chemical injection applications.
Increase the FER error cal value to set a tighter tolerance. Set the FER error cal to zero to turn off all flow monitor
alarms for the injected chemical. The default value is 8.