Sidekick Pro™ ISO Installation & Operation Manual
FIGURE 2. Boom Pressure Transducer Location
NOTE:
Sidekick Pro ISO uses these pressure transducers to verify injection status and for error detection.
To calibrate the pump transducer:
NOTE:
The following process offers a general overview of calibrating or resetting the Sidekick Pro ISO pump
pressure transducer. Refer to the operation manual for the specific control console for detailed
navigation and calibration of the pressure transducer or pressure display.
1. Turn off the injection pump and product control system and ensure there is no pressure at the pump outlet
port.
2. Select or display the set up screens for the correct product.
3. Verify no product pressure is in the injection lines.
4. Enter a value of zero for the pressure calibration value.
RATE BUMP (±)
Enter the desired rate change when using the rate increase (+) or decrease (-) soft keys on the product control
home screen.
NOTE:
The rate increase and decrease feature is only functional when the injection product is set to either
automatic or Rx mode.
Optional Boom Pressure
Transducer
Summary of Contents for Sidekick Pro ISO
Page 8: ...CHAPTER 1 4 Sidekick Pro ISO Installation Operation Manual ...
Page 16: ...CHAPTER 2 12 Sidekick Pro ISO Installation Operation Manual ...
Page 46: ...CHAPTER 4 42 Sidekick Pro ISO Installation Operation Manual ...
Page 70: ...CHAPTER 7 66 Sidekick Pro ISO Installation Operation Manual ...
Page 80: ...Index 76 Sidekick Pro ISO Installation Operation Manual ...