![Raven Sidekick Pro ISO Installation & Operation Manual Download Page 11](http://html.mh-extra.com/html/raven/sidekick-pro-iso/sidekick-pro-iso_installation-and-operation-manual_789032011.webp)
2
P/N 016-0171-509 Rev. E
7
INTRODUCTION
INTEGRATED MOTOR CONTROL NODE
Sidekick Pro™ ISO features an integrated motor control node mounted directly on the pump housing for
simplified installation and enhanced performance. The control node features status LEDs which provide status and
CAN communication information which the operator may be able to use during calibration or system
troubleshooting.
INTEGRATED CALIBRATION SWITCH
The integrated motor control node also features a sealed calibration switch. The sealed calibration switch allows
the operator to begin the pump calibration process by passing a metallic object, such as a screwdriver, across the
switch sensor on the Sidekick Pro™ ISO injection pump. This feature allows the operator to run multiple calibration
tests quickly and easily and ensure the system is ready for operation.
NOTE:
Calibration must be initiated from the control console in the vehicle cab. See the Calibrate the
Injection Pump section on page 44 for a detailed calibration procedure.
The calibration status LED light will flash when the calibration sensor registers a metallic object by the switch. Pass
the metal object past the sensor to initiate a pump calibration.
FIGURE 2. Motor Control Node Calibration Sensor
SYSTEM DIAGNOSTICS
Enhanced diagnostic features are monitored by the control console during operation of the Sidekick Pro™ ISO
injection system to help identify potential issues and minimize equipment down time. Refer to Chapter 6, Injection
Diagnostics and Troubleshooting for more information on using diagnostics features on a specific console.
FLOW MONITORING
The CAN integrated Sidekick Pro ISO offers enhanced monitoring of pump operation during chemical injection
applications to alert the operator to conditions such as an empty chemical supply tank, low injection pressure,
incorrect meter calibration, or issues with the injection pump valves.
Calibration
Sensor
Location
Calibration
Status LED
Summary of Contents for Sidekick Pro ISO
Page 8: ...CHAPTER 1 4 Sidekick Pro ISO Installation Operation Manual ...
Page 16: ...CHAPTER 2 12 Sidekick Pro ISO Installation Operation Manual ...
Page 46: ...CHAPTER 4 42 Sidekick Pro ISO Installation Operation Manual ...
Page 70: ...CHAPTER 7 66 Sidekick Pro ISO Installation Operation Manual ...
Page 80: ...Index 76 Sidekick Pro ISO Installation Operation Manual ...