34
34
RISERVATO AL PERSONALE AUTORIZZATO ALL'INSTALLAZIONE - ONLY FOR INSTALLATION-AUTHORIZED STAFF
0579-M090-0
Fig.13
L'impianto elettrico è predisposto per una tensione corrispondente a quella indicata sulla targa matricola.
The wiring system is pre-set to work at the voltage shown on the serial number plate.
380 V 60 Hz
575 V 60 Hz
220 V 60 Hz
COLLEGAMENTO MOTORE
MOTOR CONNECTION
20A
12A
COLLEGAMENTO TRASFORMATORE
CONNECTING THE TRANSFORMER
3Ph
220 V 60 Hz
20A
1Ph
FUSIBILI
FUSES
W 2 U 2 V2
U 1
V1 W 1
400
230
0
400
230
0
26
25
26
25
1 Ph
3 Ph
CAVO ALIMENTAZIONE
POWER SUPPLY CABLE
CAVO ALIMENTAZIONE
POWER SUPPLY CABLE
575
332
0
26
25
400
230
0
26
25
8A