Preparing for use
R&S
®
SMCV100B
24
Getting Started 1432.7046.02 ─ 04
b) Mate the connectors along the common axis until the male pin of the con-
nector of the cable engages with the female socket of the RF 50
Ω
con-
nector.
The connector types listed in this table represent the common connectors provi-
ded by Rohde
&
Schwarz. It is considered as general information and therefore
can contain connector types that do not apply to your instrument.
See
To prevent RF output switch-off
►
NOTICE!
If you set a too high output level without a load connected to the
instrument, the reverse power can exceed a limit forcing the R&S
SMCV100B
to switch off the RF output.
Connect a load with sufficient return loss as given in the data sheet.
4.11
Connecting to Ref In/Ref Out
The connector is located on the
To connect to Ref In/Ref Out (reference < 1
GHz)
For connection, the R&S
SMCV100B provides BNC connectors.
"To connect to non-screwable connectors (BNC)"
4.12
Connecting to Dig. IQ HS x
The Dig. IQ HS x connector comprises a QSFP+ (Quad Small Form-factor Plug-
gable) socket, that has two components: a QSFP+ cage and a QSFP+ connector.
The QSFP+ cable is equipped with the QSFP+ plug.
Connecting to Dig. IQ HS x