Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
95
Operating Manual 1176.7610.02 ─ 02
Manual operation:
See
CONFigure:BTOoth:DETector<1...4>[:FUNCtion]
<Detector>
This command selects the detector for the currently selected Bluetooth measurement.
The numeric suffix assigns the detector to a trace (1 to 4).
Note:
The RMS detector is not available for the measurements Modulation Characteristics,
Initial Carrier Frequency Tolerance, and Carrier Frequency Drift (see
on page 96).The setting is valid for the currently selected
ent of other Bluetooth measurements.
Parameters:
<Detector>
APEak | NEGative | POSitive | SAMPle | RMS | AVERage
*RST:
see table below
Example:
INST:SEL BTO
Activates the Bluetooth Measurements option.
CONF:BTO:MEAS OPOW
Activates the Output Power measurement.
CONF:BTO:DET2 RMS
Sets the detector for trace 2 to RMS.
Mode:
BT
Table 4-2: RST value depending on measurement type
Measurement type
RST value
Output Power
PEAK
Adjacent Channel Power
EDR Rel TX Power
EDR In-band Spurious Emissions
AVER
Modulation Characteristics
Initial Carrier Frequency Tolerance
Carrier Frequency Drift
EDR Differential Phase Encoding
EDR Carrier Frequency Stability and Modulation Accuracy
APEAK
CONFigure:BTOoth:IBSemissions:ACPairs
<NoChannels>
This command selects the number of adjacent channel pairs during the In–band Spuri-
ous Emissions measurement. The number of adjacent channels will be limited as soon
as the border of the Bluetooth frequency band is reached.
Note:
This command is only available with active In–band Spurious Emissions measurement
(see
CONFigure:BTOoth Subsystem (BLUETOOTH, K8)