WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
796
User Manual 1173.9657.02 ─ 11
Alg. / Step Size
It selects the power control algorithm (1 or 2) and the TPC step size (1dB or 2dB) for
TPC setups that do not use fixed values.
For description see
This parameter is available in the Combined Signal Path (CSP) scenario only. It is con-
trolled by the signaling application.
Remote command:
(CSP)
Compressed Mode Settings
Configures parameters for the TPC setup "TPC Test Step UL CM".
Pattern Selection ← Compressed Mode Settings
This parameter is available in the Combined Signal Path (CSP) scenario only. It is con-
trolled by the signaling application.
(CSP)
Pattern Type ← Compressed Mode Settings
Selects the commpressed mode pattern to be executed during the TPC measurement
in the TPC setup "TPC Test Step UL CM".
If the standalone scenario is active, this parameter selects the CM pattern which is
expected to be executed, e.g. via the WCDMA generator or an ARB file.
Note that the wrong CM configuration in the signaling application leads to the UL CM
trigger timeout.
If the combined signal path scenario is active, this parameter is controlled by the sig-
naling application.
For background information see
In the Standalone (SA) scenario, this parameter is controlled by the measurement. In
the Combined Signal Path (CSP) scenario, it is controlled by the signaling application.
Remote command:
(SA)
(CSP)
(CSP)
UL Configuration
This parameter is common measurement settings, i.e. it has the same value in all
measurements (e.g. TPC measurement and multi evaluation measurement).
For parameter descriptions refer to the multi evaluation measurement,
UE Channels
This parameter is common measurement settings, i.e. it has the same value in all
measurements (e.g. TPC measurement and multi evaluation measurement).
GUI Reference
深圳德标仪器