WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
432
User Manual 1173.9657.02 ─ 11
Manual operation:
See
2.6.11.2
Fixed Reference Channel Configuration
The following command configures a fixed reference channel.
CONFigure:WCDMa:SIGN<i>:CELL:HSDPa:FIXed:HSET
<HSet>
Selects an H-set for the fixed reference channel.
Parameters:
<HSet>
H1M1 | H1M2 | H2M1 | H2M2 | H3M1 | H3M2 | H4M1 | H5M1 |
H6M1 | H6M2 | H8M3 | H8MT | H1MI | H8MI | H3A1 | H3A2 |
H8A3 | H8AI | HAM1 | HAM2 | HAA1 | HAA2 | HCM1 | HCMT |
H6A1 | H6A2 | H1AI
Single carrier H-sets:
H1M1
to
H6M1
,
HAM1
: H-set 1 to 6, 10 (QPSK)
H1M2
to
H3M2
,
H6M2
,
HAM2
: H-set 1 to 3, 6, 10 (16-QAM)
H8M3
: H-set 8 (64-QAM)
H1MI
,
H8MI
: H-set 1, 8 (maximum input)
H8MT
: H-set 8 (maximum throughput)
Dual carrier H-sets:
H1AI
: H-set 1A (maximum input)
H3A1
,
H6A1
,
HAA1
,
HCM1
: H-set 3A, 6A, 10A, 12 (QPSK)
H3A2
,
H6A2
,
HAA2
: H-set 3A, 6A, 10A (16-QAM)
H8A3
: H-set 8A (64-QAM)
H8AI
: H-set 8A (maximum input)
HCMT
: H-set 12 (maximum throughput)
*RST:
H5M1
Example:
See
Firmware/Software:
V2.1.20
V2.1.30: additional values H3A1 | H3A2 | H8A3 | H8AI | HAM1 |
HAM2 | HAA1 | HAA2 | HCM1 | HCMT | H6A1 | H6A2
V3.0.10: additional value H1AI
Options:
R&S CMW-KS401
R&S CMW-KS403 for H-set 8
R&S CMW-KS404 for dual carrier H-sets
Manual operation:
See
2.6.11.3
CQI Test Channel Configuration
The following commands configure a CQI reporting test channel.
CONFigure:WCDMa:SIGN<i>:CELL:CARRier2:HSDPa:CQI:ENABle
.................................. 433
CONFigure:WCDMa:SIGN<i>:CELL:HSDPa:CQI:TINDex
.................................................. 433
CONFigure:WCDMa:SIGN<i>:CELL:CARRier<c>:HSDPa:CQI:FIXed
................................. 434
CONFigure:WCDMa:SIGN<i>:CELL:HSDPa:CQI:SEQuence
............................................. 434
CONFigure:WCDMa:SIGN<i>:CELL:HSDPa:CQI:FOLLow
.................................................434
Command Reference