Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
1 Basic configurations
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
36
1.6.7 Configuring SNTP
Configuring unicast feature of SNTP client
Configure unicast feature of SNTP client for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config
)#sntp server
{
ipv4-address
|
ipv6-
address
}
Configure the IP address of the SNTP unicast server.
After the SNTP server is configured with an IP address,
the ISCOM2600G-HI series switch tries to get the clock
information from the SNTP server every 10s. In addition,
the maximum timeout is 60s.
1.6.8 Checking configurations
Use the following commands to check configuration results.
No.
Command
Description
1
Raisecom#show clock
[ summer-time-recurring ]
Show configurations of the time zone and
DST.
2
Raisecom#show sntp
Show SNTP configurations.
3
Raisecom#show ntp status
Show NTP configurations.
4
Raisecom#show ntp
associations [ detail ]
Show information about NTP connection.
5
Raisecom#show ntp
authentication
Show information about NTP identity
authentication.
1.6.9 Example for configuring NTP
Networking requirements
Establish a clock synchronization system in a company to keep consistency and precision of
the system time. Basic planning is as below:
Configure Switch A as the master clock source of the clock synchronization system.
Configure Switch B as the client of the clock synchronization system. Configure the
upper-layer Switch A as the NTP server.
Configure Switch C as the NTP entity of Switch B so that Switch C receives downlink
synchronization data from Switch B.