377
Step
Command
Description
8
Raisecom(config-
service)#service
cvlan
vlan-id
(Optional) configure the customer VLAN of CFM
OAM packets. This configuration is required in
the QinQ networking environment only.
By default, CFM OAM packets do not carry C-
Tag. After the customer VLAN of the service
instance is configured, CCMs, LBMs, LTMs, and
DMMs sent by all MEPs in the service instance
will carry double Tags, of which the C-Tag is the
customer VLAN Tag configured by this
command.
9
Raisecom(config-
service)#service
priority
priority
(Optional) configure the priority of CFM OAM
packets.
After the priority is configured, CCMs, LBMs,
LTMs, and DMMs sent by MEPs in a service
instance will use the assigned priority.
By default, the priority is 7.
10
Raisecom(config)#snmp
-server trap cfm
{ all | macremerr |
remerr | ccmerr |
xcon | none } mep
{ all
|
mep-list
}
(Optional) configure the alarm level of CFM
OAM.
9.3.6 Configuring fault acknowledgement
Configure CFM fault acknowledgement for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#service
cis-id
level
level
Enter service instance configuration mode.
3
Raisecom(config-
service)#ping {
mac-address
| mep
mep-id
} [ count
count
] [ size
packet-
size
] [ source
mep-id
]
[ intercal
interval
]
[ timeout
time
] [ padding
{ prbs | pbrs-crc | null |
null-crc } ] [ cos
cos-
value
] [ non-drop
]
Perform Layer 2 Ping for acknowledging
faults.
By default, 5 LBMs are sent. The TLV
length of a packet is 64. The
ISCOM2600G-HI series switch
automatically looks for an available source
MEP.
If Layer 2 Ping is performed with the