Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
9 OAM
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
375
Step
Command
Description
4
Raisecom(config-
service)#service
vlan-list
vlan-
list
[ primary-
vlan
vlan-id
]
Configure VLAN mapping based on the service
instance.
The VLAN list contains up to 32 VLANs. If you do
not use the
primary-vlan
parameter to specify the
primary VLAN, the minimum VLAN is taken as the
primary VLAN of the service instance. All MEPs in
the service instance send and receive packets through
this primary VLAN.
The primary VLAN is used to send and receive
packets. Therefore, all non-primary VLANs are
logically mapped to the primary VLAN. This
logical VLAN mapping is global, but VLANs
cannot be crossed. For example, service
instance 1 is mapped to VLANs 10
–20 and
service instance 2 is mapped to VLANs 15
–30.
Therefore, VLANs 15
–20 are crossed. This
configuration is illegal.
5
Raisecom(config-
service)#service
mep [ up | down ]
mpid
mep-id
[
interface-type
interface-number
|
port-channel
port-
channel
]
[ priority
priority
]
Configure MEPs based on a service instance.
When configuring a MEP based on a service instance,
you must ensure that the service instance is mapped to
a VLAN.
By default, the MEP is Up. It indicates detecting
faults in the uplink direction.
6
Raisecom(config-
service)#service
sdp {
interface-
type
backup-
interface-number
|
port-channel
port-
channel-list
}
{
interface-type
backup-interface-
number
| port-
channel
port-
channel-list
}
secondary
Configure the distribution interface based on service
instance.
Only the uplink interface can be configured as the
distribution interface.
9.3.5 Configuring CFM fault detection
Configure CFM fault detection on the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.