Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
1 Basic configurations
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
26
Step
Operation
3
Type "t" to upgrade system software to the ISCOM2600G-HI series switch.
[Raisecom]:t
ipaddr: 192.168.5.100
serverip: 192.168.5.1
filename: uImage
Current system partiton info:
Partition number Name Size
----------------------------------------------------
1 iscom2600_image 16320072
2 None 0
Please input system partition number for upgrading(1-2):1
4
Type "m" to upgrade the Boot software to the ISCOM2600G-HI series switch.
[Raisecom]:m
ipaddr: 192.168.5.100
serverip: 192.168.5.1
filename: uImage mboot.bin
press y to confirm: y
5
Type "r" to rapidly execute the big BootROM file. The ISCOM2600G-HI series
switch is restarted and will load the downloaded startup file.
1.4.3 Upgrading system software through CLI
Before upgrading system software through CLI, you should establish a TFTP environment,
and use a PC as the TFTP server and the ISCOM2600G-HI series switch as the client. Basic
requirements are as below.
Connect the Ethernet interface on the TFTP server to the SNMP interface on the
ISCOM2600G-HI series switch. The default IP address of the SNMP interface is
192.168.0.1 by default.
Configure the TFTP server, and ensure that the server is available.
Configure the IP address of the TFTP server; keep it in the same network segment with
that of the ISCOM2600G-HI series switch so that the ISCOM2600G-HI series switch
can access the TFTP server.
Upgrade system software through CLI for the ISCOM2600G-HI series switch as below.