Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
7 QoS
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
297
Step
Command
Description
3
Raisecom(cos-to-pri)#cos
cos-value
to local-priority
localpri-value
[ color { green | red | yellow } ]
(Optional) modify the profile of
mapping from CoS to local priority
and color.
4
Raisecom(cos-to-pri)#exit
Raisecom(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
5
Raisecom(config-
gigaethernet1/1/1)#mls qos cos-to-
local-priority
profile-id
Apply the profile of mapping from
CoS to local priority and color on
the interface.
7.2.5 Configuring mapping from DSCP to local priority and color
Configure the mapping from DSCP to local priority and color for the ISCOM2600G-HI series
switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#mls qos
mapping dscp-to-local-priority
profile-id
Create a profile of mapping from
DSCP to local priority and color, and
enter dscp-to-pri configuration mode.
3
Raisecom(dscp-to-pri)#dscp
dscp-value
to local-priority
localpri-value
[ color { green
| red | yellow } ]
(Optional) modify the profile of
mapping from DSCP to local priority
and color.
4
Raisecom(dscp-to-pri)#exit
Raisecom(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
5
Raisecom(config-
gigaethernet1/1/1)#mls qos
dscp-to-local-priority
profile-
id
Apply the profile of mapping from
DSCP to local priority and color on the
interface. The profile used in this
configuration is the same profile used
by DSCP mutation.
7.2.6 Configuring DSCP mutation
Configure DSCP mutation for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#mls qos mapping
dscp-mutation
profile-id
Create a DSCP mutation mapping
profile, and enter dscp mutation
configuration mode.