Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
9 OAM
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
368
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#interface
interface-type interface-
number
Enter physical layer interface
configuration mode.
3
Raisecom(config-
gigaethernet1/1/1)#oam
loopback { ignore | process }
Configure the Layer 2 physical
interface to ignore or process EFM
remote loopback.
Only when the local end is configured with remote loopback response can EFM OAM
remote loopback of the peer end take effect.
Configuring OAM link monitoring
OAM link monitoring is used to detect and report link error in different conditions. When the
detection link has a fault, the ISCOM2600G-HI series switch notifies the peer of the error
generated time, window and threshold by OAM event, the peer receives event notification and
reports the NView NNM system through SNMP Trap. Besides, the local device can directly
report events from a specified interface to the NView NNM system center through SNMP
Trap.
Configure OAM link monitoring for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
3
Raisecom(config-
gigaethernet1/1/1)#oam errored-frame
window
window
threshold
threshold
Configure errored frame monitor
window and threshold.
4
Raisecom(config-
gigaethernet1/1/1)#oam errored-
frame-period window
window
threshold
threshold
Configure errored frame period
event monitor window and
threshold.
5
Raisecom(config-
gigaethernet1/1/1)#oam errored-
frame-seconds window
window
threshold
threshold
Configure link errored frame
second window and threshold.
6
Raisecom(config-
gigaethernet1/1/1)#oam errored-
symbol-period window
window
threshold
threshold
Configure errored code window
and threshold.