Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
11 Reliability
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
466
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#interface
interface-type primary-
interface-number
Enter physical layer interface
configuration mode or LAG
configuration mode.
3
Raisecom(config-
gigaethernet1/1/port)# port
backup
interface-type
backup-
interface-number
vlanlist
vlan-
list
Configure the interface backup
group.
In the VLAN list, configure the
interface
backup-interface-number
to the backup interface and
configure the interface
primary-
interface-number
to the primary
interface.
If no VLAN list is specified, the
VLAN ranges from 1 to 4094.
Raisecom(config-port-
channel1)#port backup
interface-
type
backup-interface-number
[ vlanlist
vlan-list
]
4
Raisecom(config-
gigaethernet1/1/port)#port
backup fault-detect lldp
(Optional) configure LLDP fault
detection.
5
Raisecom(config-
gigaethernet1/1/port)#port
backup restore-mode { non-
revertive | revertive [ restore-
delay
second
] }
(Optional) configure restoration
mode.
In an interface backup group, an interface is either a primary interface or a backup
interface.
In a VLAN, an interface or a LAG cannot be a member of two interface backup
groups simultaneously.
11.2.5 (Optional) configuring FS on interfaces
After FS is successfully configured, the primary/backup link will be switched; in
other words, the current link is switched to the backup link (without considering
Up/Down status of the primary/backup interface).
In the FS command, the backup interface number is optional. If different VLANs of
the primary interface are configured with multiple interface backup groups, you
should enter the backup interface ID.
Configure FS on interfaces for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.