PLEASE NOTE:
If your specific venting configuration is over 15 feet (4.5m), you must
use one of the approved direct vent venting systems that utilizes a stainless steel inner
liner. This requirement is part of the ANSI standards and is based on testing conducted
to determine where the exhaust gas temperature drops to the point where condensa-
tion might occur in the vent pipe. The standards require the use of corrosion resistant
liner materials if that specific total vent length is exceeded.
Required direct vent terminal clearances (twin pipe / concentric penetration)
English
RAIS - User manual for VIVA L Gas