16
VENTING
The VIVA L Gas Stove has been tested and listed for installation with 4” X 6
5/8” Simpson DuraVent GS®, AmeriVent Direct® , Selkirk DT® , BDM Pro-Form
DVS®, ICC EXCEL Direct® and OLYMPIA CHIMNEY SUPPLY Ventis® direct vent-
ing components.
For specific installation requirements, follow the installation instruc-
tions included by the venting manufacturer with the venting system components you
have chosen. The total vent length may not exceed 50 feet (15m), including vertical rise
and horizontal run. The vent lengths are measured from the stove, not the floor. The
minimum vertical vent rise when using a vertical vent termination is 2 feet (600mm).
The minimum vertical rise required when using a horizontal vent termination is 2 feet
(600mm). The maximum allowed horizontal vent run is 12 feet (3.6m).
For venting system installation details, refer to the instructions provided with the
venting system you have chosen. Each brand has specific installation requirements that
must be followed to insure a safe and functional venting system for your VIVA L.
English
RAIS - User manual for VIVA L Gas
Summary of Contents for Viva 100 L Classic Gas
Page 19: ...19 Vertical Roof Termination English RAIS User manual for VIVA L Gas...
Page 20: ...20 Vertical Roof Termination on angle English RAIS User manual for VIVA L Gas...
Page 21: ...21 Vertical Roof Termination with bends English RAIS User manual for VIVA L Gas...
Page 39: ...39 English RAIS User manual for VIVA L Gas Log 4 Log 3 Log 5 Log 6 Log A Log B...
Page 44: ...44 English RAIS User manual for VIVA L Gas...
Page 65: ...65 Fran ais English RAIS User manual for VIVA L Gas...
Page 69: ...7 8 3 4 5 6 1 2 9 Viva 100 L Gas Viva 120 L Gas Viva 160 L Gas...
Page 70: ...70 7 8 9 10 13 15 14 12 11 3 4 5 6 2 1 16 Viva 100 L G Gas Viva 120 L G Gas Viva 160 L G Gas...
Page 72: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk...