18
62
76
62
76
Minimum Vertical Flue Height:
-
2 feet (600mm)
Flue Restrictors to be fitted, Ø 4”x6 5/8”⅝:
Vertical Rise
< 3 feet (1m)
-
No Restrictor
Vertical Rise
3 – 8 feet (1-2m)
-
Ø62mm Restrictor
Vertical Rise
> 8feet (2m)
-
Ø76mm Restrictor
Vertical Roof Vent Termination
Flue sizing:
VIVA L :
Ø4”x6 5/8”⅝ Connector on Appliance.
Ø4”x6 5/8”⅝Maybe used Throughout, Alternatively,
Ø5”x8” Expander may be used, so that Ø5”x8” flue can be used
thereafter.
Flue Terminal: Ø4”x6 5/8”⅝Alternatively, Ø5”x8”
Minimum Vertical Flue Height:
-
20”(0.5m)
Flue Restrictors to be fitted, Ø 4”x6 5/8”⅝:
Vertical Rise
< 3 feet (1m)
-
No Restrictor
Vertical Rise
3 – 8 feet (1-2m)
-
Ø62mm Restrictor
Vertical Rise
> 8feet (2m)
-
Ø76mm Restrictor