12
English
RAIS - User manual for VIVA L Gas
SPECIFICATIONS
INPUT
Natural Gas
Propane (LP)
Input
Rating-Btu/hr
31,000
25,600
Min.
Input-Btu/hr 8,000
8,000
Orifice-Marking
(Front)
120
80
Orifice-Marking
(Rear)
260
(x2)
100
(x2)
GAS SUPPLY
Manifold Pressure
4.0”w.c. / 1.0kPa
10.8”w.c. / 2.7kPa
Min. Supply Pressure
4.0”w.c. / 1.0kPa
11.0”w.c. / 2.8kPa
Max. Supply Pressure
10.0”w.c. / 2.5kPa
13.0”w.c. / 3.3kPa
EFFICIENCY
Steady State Efficiency (At Min. Input Rate and Using Minimum Allowable Vent
Length)-%
Top Vent / Rear Vent
78
78.2
Annual Fuel Utilization Efficiency [AFUE](Using Minimum Allowable Vent Length) -%
Top Vent / Rear Vent
77
77
Canadian p.4 Efficiency (Using Minimum Allowable Vent Length)- %
Top Vent / Rear Vent
70 / 72
69 / 70
Maximum Observed
-Steady State Efficiency -%
73.6
70.1
NOTE:
The maximum achievable steady state efficiency can vary depending the installa-
tion and on how the stove is operated.
It is recommended that the pilot flame be turned off if the appliance will not be in use
for an extended period of time. This appliance is equipped for use with the fuel type
indicated on the rating plate. Fuel conversion kits that include the necessary parts and
instructions are included with the stove or are available from your installer, dealer or
RAIS.
This appliance has been certified by Intertek, Inc. to ANSI Z21.50 • CSA 2.22 Vented
Gas Fireplace Heaters and CGA 2.17-M91 (R2009), Gas-Fired Appliances for Use At
High Altitudes.
The VIVA L is approved for installation at elevations up to 4500 feet (1370 meters) in
U.S. and Canada without change. If your installation is at an elevation greater than
these, consult with the local authority having jurisdiction for gas product installations to
determine their specific requirements for high altitude installations.
Intertek Testing & Certification Ltd,
Registered office: Academy Place, 1 to 9 Brook Street, Brentwood, Essex
CM14 5NQ, United Kingdom. Registered No: 3272281
(England), VAT No: GB 672-7639-96-011
T: +44 1277 223 400
F: +44 1277 223 127
Summary of Contents for Viva 100 L Classic Gas
Page 19: ...19 Vertical Roof Termination English RAIS User manual for VIVA L Gas...
Page 20: ...20 Vertical Roof Termination on angle English RAIS User manual for VIVA L Gas...
Page 21: ...21 Vertical Roof Termination with bends English RAIS User manual for VIVA L Gas...
Page 39: ...39 English RAIS User manual for VIVA L Gas Log 4 Log 3 Log 5 Log 6 Log A Log B...
Page 44: ...44 English RAIS User manual for VIVA L Gas...
Page 65: ...65 Fran ais English RAIS User manual for VIVA L Gas...
Page 69: ...7 8 3 4 5 6 1 2 9 Viva 100 L Gas Viva 120 L Gas Viva 160 L Gas...
Page 70: ...70 7 8 9 10 13 15 14 12 11 3 4 5 6 2 1 16 Viva 100 L G Gas Viva 120 L G Gas Viva 160 L G Gas...
Page 72: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk...