31
English
RAIS - User manual for VIVA L Gas
Replace the two nozzles for the secondary
burners by loosening the coupling and care-
fully pulling the pipe out. Loosen the lock-
nut and then unscrew the nozzle. Fit the
LPG nozzle and tighten the lock nut. Finally,
re-tighten the coupling.
Once the gas unit has been dismounted, replace the four nozzles and
adjust the three air intakes.
Now the gas unit can be lifted out carefully
by tilting and rotating the unit a little.