Rain Master Irrigation Systems
RME EAGLE User Manual
Chapter 6 Setup Key Operations
Page 81
6.13.7 Limits
The Limits feature will allow you to set the station's upper flow limits by either using the LEARN
mode or by setting them explicitly. The next 2 sections explain each of these methods.
NOTE:
This SETUP function will be skipped if you have not enabled the flow
features.
6.13.7.1 Station Limits Using Learn Mode
This feature allows the controller to LEARN and set the station upper flow limits.
Controller operation:
•
Each station is turned on one at a time. The amount of time it is on is determined by
the flow check delay time (1 to 6 minutes).
•
The nominal flow reading is established by averaging the measured flow for the last
minute in which the station is on.
•
The station upper limit is calculated taking the nominal value and adjusting upward by
the flow percentage (previously established).
•
The new limit is saved in memory (non-volatile RAM).
You just press ENTER and the controller will automatically set the upper flow limits by
LEARNING them.
EXAMPLE:
Set the controller to LEARN and automatically set all the station upper flow limits.
You think 30% is a good amount to add to the upper limits over and above what the
controller measures.
Continue
to
Press:
Until display indicates:
Press:
Press:
Display will indicate:
Press:
Display will indicate:
PERCNT30
PROGRAM
SETUP
P E R C N T 2 0
PROGRAM
ENTER
SETUP
3
TUE
0
L I M I T S
PROGRAM
SETUP