Chapter 9 Troubleshooting
Symptom
Action
Flow reading “000 GPM”
when water flowing
Check installation/connections.
The following table lists some common ET error symptoms and corrective actions.
Table 10 - ET Troubleshooting Assistant
Symptom
Action
Water Percentage Budget is
always equal to PT – XXX
(should be: ET – XXX)
1. Enable the irrigation program for ET operation (See 7.2 ET
MODE).
ET programs are always over
watering.
Press the Water % Budget
key, the display indicates:
ET – 1XX
1. Verify that you have obtained the correct historical ET data
(See 8.2 OBTAINING THE HISTORICAL ET DATA).
2. Verify that the reference program has been properly entered
(See 8.3 GENERATE THE REFERENCE PROGRAM).
3. Verify that you have entered the correct ET reference value
(See 8.4 ESTABLISH THE ET REFERENCE VALUE).
The station runtimes in ET
programs never change.
Press the Water % Budget
key, the display indicates:
ET – 100
1. Verify that you have entered the correct ET reference value
(See 7.3 ENTERING THE ET REFERENCE VALUE).
2. Verify that you have entered the Historical ET Monthly values
(See7.4 ENTERING HISTORICAL ET MONTHLY VALUES).
Weather Station device is
enabled, but display indicates
historical data is being used.
Press the ET key, the display
indicates: ET – H .XX
(should be: ET – D .XX)
1. Device must have a 24 hour (midnight to midnight)
accumulation before the Weather Station data is considered valid
and then used in runtime calculations.
2. If power is lost for more than one (1) hour, the controller will
use historical ET data.