Rain Master Irrigation Systems
RME EAGLE User Manual
Chapter 9 Troubleshooting
Page 105
= The problem is an Unscheduled Flow limit violation. Pressing the
REVIEW key reveals the measured GPM at the time the fault
occurred.
=
The problem is a station Upper Flow limit violation. The station lights
illuminate to show which station(s) are involved. Pressing the
REVIEW key again reveals the measured GPM at the time the fault
occurred.
Whenever a specific fault is displayed it can be cleared by pressing the CLEAR key. If the CLEAR
key is not pressed, the QUIT key will return the controller to the Automatic Mode without clearing
the fault condition.
9.2.1 Wiring Fault
The RME EAGLE has been equipped to detect station short circuits which may occur due to
improper field wiring or faulty valve solenoids. In the event a station draws excessive electrical
current, the following action occurs:
•
The offending station will be immediately turned off.
•
The next scheduled station of the program will be started.
•
FAULT…PRESS…REVIEW…will appear in the display.
•
The controller will continue to execute programs; however, any faulted station(s) will not be
turned on again.
NOTE:
If multiple stations are on simultaneously, and the controller detects an
over current fault, all running stations will be diagnosed as faulty.
NOTE:
If a short circuit occurs at the Normally Closed Master Valve and the
program has been SETUP to use a Master Valve. The controller will
successively condemn all remaining stations in the program. Upon
reviewing the fault, all stations of the program shall illuminate, indicating
that the problem appears to be the Master Valve.
User Action:
1.
Excessive station current may be due to an inadvertent direct connection between the station
wire and the common wire.
2.
Check for exposed wiring in a flooded valve box.
3.
Check for a faulty valve solenoid.
4.
When corrective action has been completed, the fault should be cleared.
FLOW UN
PROGRAM
FLOW STA
PROGRAM