DRAFT
Operator’s Manual
© Copyright 2014 - Rail-Ability Limited
Page
23
of
64
Conversion
Note that it is possible to overstress and overturn the machine while the safety systems are
overridden. The operator should prioritise the use of the Radius in function wherever possible
to assist in correcting the situation.
Once the booms have been lowered to a stowed position, after the over-ride key has been activated,
the blue LED strip will be off indicating that the machine is overridden. The machine must be inspected
and reset by Rail-Ability Ltd prior to being put back into service.
Figure 3 - Engine Bay Over-ride Button Location
10.2 Battery Driven Pump
The battery driven hydraulic pump is activated via the in cab onscreen display auxiliary hydraulics
function menu.
The electric pump will not run if the main pumps are operating or if the batteries are discharged below
21 volts.
10.3 On Rail Recovery
10.3.1 Towing
Refer to the manuals detailed in section 4 and adhere to all instructions before commencing
towing.
Ensure that the towing machine is connected with the tow bar before the rail brakes are
released via hub disengagement, to enable towing to commence:
A Network Rail pattern tow bar is located at the rear of the machine
Only use the rigid tow bar provided
Tow eyes and pins are fitted to the front and rear of the machine.