4
M16MI377 - A07-06/18
INSTALLATION & MAINTENANCE
EN
3.CONNECTIONS
The electrical installation must comply with local or national regula-
tions. This appliance must be installed by a competent electrician.
3.1 ELECTRICAL CONNECTION
• The technical characteristics of your appliance are shown on
the data plate located on the side of the appliance. Please take
note of these before any request for After sales service.
• Any interventions on electrical parts must be done by a quali-
fied professional.
• Enclosure class IP44,
• Connect the 3 core cables as follows:
Brown wire = Live
Blue wire = Neutral
Black wire = Control Wire (Pilot Wire)
This wire must never be connected to the earth and must be
isolated,
• RCD of 30mA maximum is compulsary for bathrooms or
shower rooms (must be isolated if not used),
• This appliance must be connected to the fixed wiring through
a cable outlet (13A max) and controlled through a double pole
switch having a contact separation of at least 3mm in all poles,
• The radiator is supplied with a 0,8 m cord,
• Supply voltage 230-240V,
• For installation in a bathroom (to comply with current IEE regu-
lations) the appliance must be wired in
the manner prescribed with the double pole switch mounted
outside the bathroom.
If the supply cord on this product is damaged, it must be re-
placed by the manufacturer, its service agent, or other qualified
person.
This radiator is filled with a precise quantity of liquid, any
repairs that involve opening the radiator must be carried out
by the manufacturer or his service agent. Any leakage must be
dealt with by the manufacturer or his representative.
• The factory fitted power cable must be connected to the
mains by a junction box which will have to be placed behind the
appliance, without putting in a power socket and which will be
located at least 250 mm from the floor.
• If the supply cable is damaged, it must be replaced by a specific
cable. Replacement of this cable must
be done by the manufacturer, their after sales service or people
with similar qualifications in order to
avoid any danger.
• The heated towel rail is filled with an exact quantity of heat
transfer fluid. Repairs requiring opening of
the bathroom heater must only be carried out by the manufac-
turer or their after sales service who must be contacted if there
is any leak of heat transfer fluid.
• When the appliance is thrown away, elimination of the heat
transfer fluid must only done by approved subcontractors.
4. CONDITIONS OF USE
Refer to the paragraph WARNINGS in point 1. General information
• The heater can be used continuously without any risk.
• For operating the electronic regulation refer to the operating instruc-
tions.
5.MAINTENANCE TIPS
Maintenance operations must be done with the heater switched off.
Therefore take care the appliance is
off. In order to ensure your heater lasts, we recommend you use the
following few tips:
• Use only mild cleaning agents when cleaning and wiping of the
radiator is necessary.
• Use a dry cloth (without solvent) for the control unit.
• Use warm soapy water for cleaning the outside walls of the heater
(no abrasive or corrosive product).
• This heating appliance is filled with an exact quantity of glycoled
water.
depending on appliances. Repairs requiring opening of the reservoir
must only be carried out by the manufacturer or their after sales ser-
vice who must be contacted if there is any leak of glycoled water.
This fluid, specially developed for this use does not require any particu-
lar maintenance.
WASTE DISPOSAL ACCORDING TO THE WEEE DIRECTIVE (2012/19/UE)
The symbol on the product label indicates that the product may not
be handled as domestic waste, but must be sorted separately. When
it reaches the end of its useful life, it shall be returned to collection
facility for electrical and electronic products. By returning the product,
you will help to prevent possible negative effects on the environment
and health to which the product can contribute if it is disposed of as
ordinary domestic waste. For information about recycling and
collection facilities, you should contact your local authority/muni-
cipality or refuse collection service or the business from which you
purchased the product. Applicable to countries where
this Directive has been adopted.
WASTE MANAGEMENT OF ELECTRICAL EQUIP-
MENT AND ELECTRONICS IN ACCORDANCE WITH
WEEE DIRECTIVE 2012/19/UE
ROHS: COMPLIES WITH THE DIRECTIVE 2011/65/UE
Summary of Contents for ESSENTIAL THERMOSTAT