12
M16MI377 - A07-06/18
USER SETTINGS
ACCESS
You access to user settings in 3 steps:
From Auto, Comfort, Eco or Frost protection mode :
Information
display
mode
auto
prog
OK
boost
1
Information
display
mode
auto
prog
OK
boost
1
User
= User settings
mode
auto
prog
OK
boost
Press for 5
seconds
1
Press briefly
twice
2
Press briefly
3
Setting sequence:
Eco mode temperature lowering-level
Frost protection temperature
Comfort setting temperature limit
Maximal Boost duration
Maximum ambient temperature
Temperature unit
SE
TTING THE ECO MODE TEMPERATURE
LOWERING-LEVEL
The drop in temperature is set at -3.5°C compared to the set tempera-
ture of the Comfort mode. You can adjust the lowered level from -1°C to
-8°C, by intervals of 0.5°C.
Important: whatever the lowering level set, the Eco setting tempera-
ture will never exceed 19°C.
3
- Press
or
to obtain the temperature level you require.
mode
auto
prog
OK
boost
SETTING THE FROST PROTECTION
TEMPERATURE
Your device is preset at 7°C. You can adjust the Frost protection
temperature from 5°C to 15°C, by intevals of 0.5°C.
6
- Press
to save and move to the next setting.
To exit the user settings, press
twice.
5
- Press
or
to obtain the temperature you require.
mode
auto
prog
OK
boost
To exit the user settings, press
twice.
4
-
Press
to save and move to the next setting.
mode
auto
prog
OK
boost
COMFORT SETPOINT TEMPERATURE LIMIT
You can limit the setting temperature range by introducing a maximum
and / or minimum setting, preventing unintentional changes in tem-
perature.
• Low temperature limit
Locking of the setting range using a minimum temperature stop, pre-
venting the temperature from being set below that temperature.
The minimum setting is preset to 7°C. You can adjust from 7°C to 15°C
by intervals of 1°C.
7-
To change the minimum temperature setting, press
or
then
save by pressing
.
If you do not want to change it, press
: the device changes auto-
matically to set the maximum setting. To exit the user settings, press
twice.
mode
auto
prog
OK
boost
2
1
EN
Summary of Contents for ESSENTIAL THERMOSTAT