thermal safety as well as the flap for fire initiation. All parts of the water portion of boiler are
made of seamless pipe ST 35.4 quality and boiler plate thickness of 5 mm or more, depending on
the power of boiler. Sheets are of the quality of the Standard 1.0425 EU i.e. Standard P265GH
EUII
.
Figure1. Cross-section of BIOmax boiler
Combustion chamber (figure2, pos. 2
), in it’s princ
iple of work. The so-called,, spring up ",
where the zone of transport of fuel is going vertically upwards i.e. it springs up to the
combustion zone. It is made of solid insulating materials and cast iron.
Fuel transport (figure 2, pos.4) is provided by screw transporters. There is a noticeable
difference in the feeder for BIOmax23.1 and the feeder for BIOmax35. In fact, there is the
difference in the form of valves for setting the air assembled onto the feeder of BIOmax23.1, all
these in order to get the best possible emission of flue gases (figure 2) , further explained in text
in item 8.2. The fuel is coming from the silo of the capacity of 240 L (figure 2,pos.5). If
necessary, it is easy to dismantle the whole assembly into three independent entities: silo, the
mechanism for setting and boiler
.
(figure 2)