36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
99
Figure 19. Showing removing of turbulence unti from the boiler BIOmax and removal of cast
segments of furnace
If, during the cleaning in the boiler there appears the condensation it is necessary to collect the
condensed matter and the whole boiler inside should be coated by base means for cleaning or
else by means of water solution of constyruction lime. In this way the neutralization of acids is
carried out due to condensation.
In this way the boiler is conserved at the end of the heating season. In this
situation, close all openings of the boiler to prevent the circulation of air through
the boiler as the moisture can occur in the boiler as well.
Maintenance of the boiler is one of the most essential factors for the length
of working life of the boiler. It is particularly important that the boiler be cleaned
when out of operation season and neutralization of acids be done as already
described.