Where is:
Valve 1 : Open 100 %
Valve 2 : Open 100 %
Flap ( on feeder ) : lowered up to line mark
The primary fan : 23%
The secondary fan : 18 %
Loading the feeder : 2.5 s
Pause between loading the feeder : 8.5 s
Valve position for minimum power at the work:
Where is:
Valve 1: Open 15
˚
Valve 2 : Open 45
˚
Flap ( on feeder ) : lowered up to line mark
The primary fan : 17 %
The secondary fan : 18 %
Loading the feeder : 0.5 s
Pause between loading the feeder: 6,5 s
The room thermocouple (thermostat) can be connected to automation system. In this case,
it is important to adjust the room temperature, which is the main parameter for the
operation of the boiler and water temperature in boiler (70
˚
C). When the room
thermostat is activated, the boiler has the first need to reach the room temperature, under
the condition that it is limited by adjusted degree of water temperature in it. There is a
possibility that the boiler stops working before the adjusted temperature of the room
thermostat, in this case the set temperature of the water in the boiler should be raised,
Example to: 70
˚
C.