If you think that the chimney is too strong and too much cold air passes through the boiler, at the
exit of the boiler there is a valve which can reduce the flow of exhaust gases. The chimney
should be cleaned regularly or at least once a year.
If the chimney is not of proper height, cross section, or if it is not enough
clean as possible, then the complications in the work of boiler are possible. First,
of all it is not possible to achieve the high teperature regime of work, i.e. there is
not the maximum operation power, and the consequence of that is the
occyrrence of condensation which affects the life of the boiler.
Weak/poor chimney is the main reason when during the ignition of the
boiler or during the operation there is the appearance of smoke on the upper or
lower door, especially at higher fan speeds.