8.1 Control board
Control panel consisting of:
The main switch, safety thermostat button, the display, the group command buttons (buttons), a
group of light-emitting diode pointer.
The picture below is the image of the Control Panel.
8.1.1 Buttons
Button
Function
K1
With a Click enters to modify the value of the Boiler thermostat: Led L3
blinking: with buttons K2 and K3 modify the actual set value.
A long pressure enters to modify the function Winter/ Summer signalled
by the led L1/L2.
In modify parameters saves the set value.
K2
With a Click enters to modify the value of the Working time of the
cochlea engine: Led L7 blinking: with buttons K2 and K3 it is possible
to modify the actual set value.
A long pressure activates the manual loading of the combustible for the
length of the pressure activating the cochlea engine: the display shows
LoAd. The procedure is possible only with state OFF.
With a safety valve the loading starts after the timer T72.