36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
64
Maximum operating pressure of the boiler is 3 bar, 1 bar the minimum and
maximum operating temperature of the boiler is 110 C.
Boiler with 2 fans, automation and ceramic heaters for wood and all of these
devices use 230V power, so that incorrect installation and careless handling may endanger
human life electrocution.
Solid fuel boiler and forced draft should be installed according to valid standards
and legal regulations. Any mechanical or electrical change in the design or installation shall
be deemed a violation of guarantee conditions and will lead to its distortion.
In an assembly the boiler should be properly protected against the excessive
overpressure and overheating.
When installing the hydraulic installation of the boiler must be provided in a
prescribed way of overdraft maximum operating temperature and pressure.
For the proper installation the plumber/installer is responsible.
The manufacturer (Radijator inzenjering) does not take any responsibility coming
from the incorrect installation of the boiler.
When any intervention on the electrical devices BIOmax , the whole system off the
main power supply.
The basic requirements to be complied with during the installation
:
-
The boiler can be connected to an open system of central heating, but also to a closed
system of central heating. In case of connection to a closed system, it is recommended to
install the valve for thermal insurance, which is determined by the respective laws of
each state in which the boiler is connected.
-
The boiler must be located at a safe distance from combustible materials.
The boiler must be far enough from possible obstacles in the boiler room for cleaning and
maintenance.See figure 9.
-
Electric power for the boiler is 230V 50Hz and connection of all devicesthat the boiler
has should be done according to valid regulations and connection is done by a person
with proper authority.
-
Connection to the chimney also done according to the binding regulations and
manufacturer's recommendations as can be seen below
.