Remote
Up to 256 Remote stations can be configured under one Base station. Any Remote station
[stand-alone, repeater or behind a repeater] must also be configured in Base station/Radio
protocol/Remotes.
If a frame needs to be routed from one Remote station to another Remote station, it must
be routed through the Base station. Appropriate routing rules must be defined.
Italicised parameters
are described in Common parameters.
Protocol address mode
List box: Automatic, Manual
Default = Automatic
Radio protocol address can be determined in two different ways:
Automatic
Protocol address is the same as the last byte of Radio IP address.
Manual
Protocol address is set up manually (see parameter Protocol address).
Protocol address
Default = 1 [0 – 255]
Can only be configured only when Protocol address mode is set to Manual.
The same Protocol address must be set in the Base station/Radio protocol/Remotes.
Advanced parameters
RipEX Radio modem & Router – © RACOM s.r.o.
130
Advanced Configuration
Summary of Contents for RipEX
Page 2: ......