Internal Errors and Warning displayed by monitoring
■
Errors (red background)
○ Requested monitoring data missing
Required data for monitoring are not available for an unknown reason.
Can be displayed on an independent line while any interface is being monitored.
○ RF preheader error
"RF-preheader" is a part of header transmitted by the most robust modulation.
Displayed while "RADIO" (Rx) interface is being monitored as part of a packet header.
○ RL header CRC error
"RL-header" is Radio Link protocol header.
Displayed while "RADIO" (Rx) interface is being monitored as part of a packet header.
○ Bridge stream datablock header CRC error
"Bridge stream DB-header" is header of Data block transmitted while Operating mode is Bridge
and Frame closing (COM) is Stream.
Displayed while "RADIO" (Rx) interface is monitored as part of a packet header.
○ Data CRC error
Data CRC error.
Displayed while "RADIO" (Rx) interface is monitored as part of a packet header.
■
Warnings (yellow background)
○ Record sequence problem - reconfiguration?
There is a problem in sequence of records. The system may have to be reconfigured with other
Settings or Routing pages.
Can be displayed on an independent line while any interface is being monitored.
○ Record sequence problem. Some records may be lost.
There is a problem in sequence of records for an unknown reason. One or more records have
been lost.
Can be displayed on an independent line while any interface is being monitored.
○ [x] missing record(s) detected
"x" (replaced by specific number) records are missing.
Can be displayed on an independent line while any interface is being monitored.
○ Monitoring restarted. Some records may be lost.
Monitoring system has been restarted e.g. because of monitoring configuration change. Some
records may be lost.
Can be displayed on an independent line while any interface is being monitored.
○ ETH monitoring terminated. Invalid tcpdump parameters?
Monitoring of ETH interface has been stopped. Probably because of unsupported or wrong
'tcpdump' syntax in Monitoring/ETH/Advanced parameters/User rule.
Can be displayed on an independent line while ETH interface is being monitored.
○ Interface not ready!
RF interface is not ready. May happen when system is booting, after reconfiguration, after radio
part recalibration made automatically after some time etc. The packet is discarded.
Displayed while "RADIO" (Tx) interface is being monitored as part of a packet header.
RipEX Radio modem & Router – © RACOM s.r.o.
196
Advanced Configuration
Summary of Contents for RipEX
Page 2: ......