Neighbours&Statistics
Parameters
List box: Default, Manual
Default = Default
Default
Default (recommended) values are set and can not be edited.
Manual
Values can be set manually.
There are 2 tables with diagnostic information in the main menu - Diagnostic/Neighbours, Dia-
gnostic/Statistic. The Neighbours table displays Watched values from RipEX and from all its
neighbours. (Neighbour = RipEX, which can be accessed directly over the radio channel, i.e.
without a repeater). There is statistic information about the traffic volume in the Statistic table.
Watched values broadcasting period [min]
Default = 120 min, [0 = Off]
RipEX periodically broadcasts its Watched values to neighbouring units. The Watched values
can be displayed in Graphs and Neighbours menu.
NOTE 1:
When Bridge mode is used, Watched values broadcasting creates collisions for user traffic.
Be careful when using this feature.
NOTE 2:
When Router with Base driven Radio protocol is used:
•
Watched values from Remote stations are only transmitted to the Base station.
•
Watched values from the Base station are broadcast to all Remote stations.
•
Repeater station receives Watched values from the Base station and from all Remote
stations behind it.
Neighbours&Statistic log save period [min]
Default = 1440 min (1 day) [10 - 7200 min]
This is the period, in which Neighbours and Statistics logs are saved in the archive and
cleared and new logs start from the beginning.
NOTE 1:
The history files are organized in a ring buffer. Whenever a new file is opened, the numbers
of files are shifted, i.e. 0->1, 1->2, etc. There is a history of 20 log files available.
NOTE 2:
The Max value is 6.000.000 min. (more than 11 years) It used to be only 7.200 min. up to
the 1.3.x.x fw version.
111
© RACOM s.r.o. – RipEX Radio modem & Router
Advanced Configuration
Summary of Contents for RipEX